MSI MS-9652 Manuel d'utilisateur Page 40

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 126
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 39
Report No 094061R-ITCEP07V06
Page: 37 of 123
Site : SR-1 Time : 2009/04/01 - 00:42
Limit : CISPR_B_00M_AV Margin : 0
EUT : Notebook Probe : ENV-216-N - Line2
Power : AC 230V/50Hz Note : Mode 2
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV)
Margin
(dB)
Limit
(dBuV)
Detector Type
1 * 0.201 9.860 40.700 50.560 -3.983 54.543 AVERAGE
2 0.400 9.840 30.830 40.670 -8.187 48.857 AVERAGE
3 0.931 9.830 26.780 36.610 -9.390 46.000 AVERAGE
4 1.927 9.850 20.350 30.200 -15.800 46.000 AVERAGE
5 4.326 9.870 11.670 21.540 -24.460 46.000 AVERAGE
6 23.130 10.130 29.160 39.290 -10.710 50.000 AVERAGE
Note:
1. All Reading Levels are Quasi-Peak and average value.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor